HOW TO CONNECT ALKALINE MINERAL FILTER TO REVERSE OSMOSIS
Attach as last stage before faucet
See Picture Below For Reference
1. The pH alkaline mineral filter should go between the Auto Shut-off Valve and the RO Tank. It provides better result than installing it before the faucet, as is sometimes done.
2. The filter has two openings on the top. The one in the center of the filter is the OUTLET; the one on the edge is the INLET.
3. It this is the first time you ordering this filter, then it should come with two separate connectors to connect onto the outlet and inlet ports. If ordered before, then you should already have those connectors.
4. IF you had existing alkaline filter installed before the faucet, you can remove it. Cut a segment of 1/4" water line from elsewhere on the system to use to bridge the gap left by the removed filter.
Most connection uses quick connect fittings. Click Here For Tips on Working With Quick